<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-01 00-14-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 69 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 2.8 kHz 89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 65 kHz 19003 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,7 dBr 1,85 dBr 2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"London Classical Players "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 65 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/01 0.13.14 Total samples: 19003 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500